Is used at PEDESTRIAN and POST/BAGGAGE checkpoints
Detection thresholds, no more than
Width of the search area 1.5 m |
Cs - 137 |
25 kBq |
Со - 60 |
13 kBq |
Ва - 133 |
20 kBq |
Рu |
0.15 g |
U |
6 g |
Рu shielded |
35 g |
Note:
Pu - sample of highly-enriched Pu-239, U - sample of highly-enriched U-235
Detection channels |
gamma, neutron |
Gamma detector |
1 plastic 4.6 L |
Neutron detector |
3 counters 0.6 L each |
Parameters of the search area1 |
Width |
1.5 m |
Height |
0.7 m |
Speed of the controlled object |
5 km/h |
Power consumption |
45 W |
Operating temperature |
From -50°С to +50°С |
Overall dimensions of a pillar |
2750x1898x572 mm |
Weight |
170 kg |
Detection probability of the given masses of nuclear materials is 0.5 at level of confidence 95%, maximum background intensity 20 μR/h and maximum false alarm rate 1/1000
Note:
Can be supplied without neutron channel
| |