PURPOSE
Measurement of the gamma radiation equivalent
APPLICATION
As a part of radiation control systems at NPPs, nuclear cycle facilities, radiological laboratories
FEATURES
- Functionally completed network-intagrable device
- Nonvolatile archive (up to 240 measurement)
- Alarm control unit
- Self-diagnostics
Modification |
Purpose |
Complete set |
UDBG - 01 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
- Two-level visual and sound alarm
- Connection of additional detector
|
- BDG-02* gamma detector
- BK-01 switching unit
- BS-01 alarm unit
- Bracket
|
UDBG - 01 - 01 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
- One-level visual and sound alarm
- Connection of additional detector
|
- BDG-02-01* gamma detector
- BK-02 switching unit
- Bracket
|
УДБГ - 01 - 02 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
|
- BDG-02* gamma detector
- Bracket
|
УДБГ - 01 - 03 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
- Connection of additional detector
|
- BDG-02* gamma detector
- BK-02 switching unit
- Bracket
|
УДБГ - 04 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
- Two-level visual and sound alarm
- Connection of additional detector
|
- BSCh-01counter unit
- BKK-01 control and switching unit (with alarm)
- Cable, 50m
- Bracket
|
УДБГ - 04 - 01 |
- Measurement of photon radiation EDR
- Storage of measured data in the detector archive
- Connection of additional detector
|
- BSCh-01counter unit
- BKK-01-01 control and switching unit
- Cable, 50m
- Bracket
|
TECHICAL DATA OF UDBG-01, UDBG-01-01, UDBG-01-02, UDBG-01-03
Detector |
GM counter |
EDR measurement range, μSv/h |
0,1 105 |
Detected energy range, MeV |
0,06 1,5 |
Energy dependence of sensitivity relative to the energy 0,662 MeV (137Cs), % |
±25 |
Tolerable basic relative error of EDR measurement, % |
±20 |
Protection class |
IP65 |
Operating temperatures, °С |
-40...+50 |
Power voltage, V |
9 18 |
Interface |
RS-485 |
Protocol |
MODBUS |
OVERALL DIMENSIONS AND WEIGHT
|
Overall dimensions, mm |
Weight, kg |
|
UDBG - 01 |
155 x 162 x 515 |
4,8 |
Foto |
UDBG - 01 - 01 |
155 x 162 x 393 |
2,8 |
Foto |
UDBG - 01 - 02 |
155 x 114 x 264 |
1,86 |
Foto |
UDBG - 01 - 03 |
155 x 162 x 264 |
2,46 |
Foto |
*BDG-02 detector can be supplied separately
TECHNICAL DATA OF UDBG -04, UDBG-04-01
Detector |
GM counter |
EDR measurement range, μSv/h |
0,1 107 |
Detected energy range, MeV |
0,06 1,5 |
Energy dependence of sensitivity relative to the energy 0,662 MeV (137Cs), % |
±25 |
Пределы допускаемой основной относительной погрешности измерения МЭД , % |
±20 |
Protection class |
IP65 |
Operating temperatures, °С |
-40...+50 |
Power voltage, V |
9 18, 50 |
Interface |
RS-485 |
Protocol |
MODBUS |
OVERALL DIMENSIONS AND WEIGHT
|
Overall dimensions, mm |
Weight, kg |
|
UDBG - 04 |
|
|
|
|
Foto |
114 x 195 x 155 |
220 x 120 x 137 |
0,7 |
4 |
UDBG - 04 - 01 |
114 x 195 x 155 |
220 x 120 x 81 |
0,7 |
3,5 |
Foto |
|