Aspect SPC
About the companyServicesContactsCertificates News     russian  
-Products-
Radiation Monitors and Systems
Dosimetry and radiometry
Nuclear radiation detectors
PC-based MCA
Modular nuclear electronics
Nuclear radiation spectrometers
Inspection systems
Shielding screens
Dedicated equipment
Software

gamma detector UDBG
beta detector UDBB
alpha-beta surface contamination detector BDA-01
neutron detector UDBN
local controller units BLK
alarm unit BS-01
beta contamination control system RZB-01A
calibration device UK-01
power supply and switching unit BPK
contamination probe IRS-02A
neutron search detector NSD-A03
NPP personnel contamination control system
NPP personnel contamination control system RZS-02A

To main page / Dosimetry and radiometry

NEUTRON DETECTOR UDBN


PURPOSE

Measurement of the neutron radiation equivalent dose rate

APPLICATION

As a part of radiation control systems at NPPs, nuclear cycle facilities, radiological laboratories

FEATURES
  • Functionally completed network - integrable device
  • Nonvolatile archive (up to 200 measurements)
  • Alarm control unit
  • Data transfer and access to the parameters of the detecting unit via the RS - 485 channel


  • Modification Purpose Complete set
    UDBN - 01
    • Measurement of neutron radiation EDR
    • Storage of measured data in the detector archive
    • Two - level visual and sound alarm
    • Connection of additional detector
    • BDN - 01 neutron detector
    • BK - 01 switching unit
    • BS - 01 alarm unit
    • Brackets
    UDBN - 01 -01
    • Measurement of neutron radiation EDR
    • Storage of measured data in the detector archive
    • Two - level visual and sound alarm
    • Connection of additional detector
    • BDN - 01 neutron detector
    • BK - 02 switching unit
    • Brackets
    UDBN - 01 - 02
    • Measurement of neutron radiation EDR
    • Storage of measured data in the detector archive
    • BDN - 01 neutron detector
    • Brackets

    TECHNICAL DATA OF BDN - 01

    EDR measurement range, μ Sv/h 0,1 – 104
    Detected energy range, MeV 10-3 – 14
    Sensitivity against Pu-α-Be, (pulse/s)/(μ Sv/h) 0,4
    Tolerable basic relative error of EDR measurements, % ±30
    Operating temperatures, °С От -40 до +50
    Protection class IP65
    Power supply, V, mA 9 – 18, 50

    OVERALL DIMENSIONS AND WEIGHT

     
    UDBN - 01
    UDBN - 01 - 01
    UDBN - 01 - 02
    BDN - 01
    Overall dimensions, mm
    Weight, kg
    337 x 300 x 741
    21,7
    337 x 300 x 460
    19,4
    337 x 300 x 460
    18,6
    402 x Ø300
    16,5

    Print version

    site map e-mail developed by cre8 bureau