| | | | | | | | | | | | | | | | | | | | | | | | | NPP personnel contamination control system RZS-02A | |
|
|
/
NPP PERSONNEL CONTAMINATION CONTROL SYSTEM RZS-02A | |
PURPOSE
Implementation of sanitary access mode at NPPs under construction and reconstruction for contamination control of:
- Protective clothing, shoes and other means of personal protection at the exit from limited access area to the working clothes change room of decontamination station;
- Personnel skin and head at the exit from shower cabins to the personal clothes change room of decontamination station.
FEATURES
- Combined detecting units of domestic manufacture based on plastic scintillators – 24 items;
- Separate recording and processing of beta and gamma radiation by each detecting unit;
- Automatic gamma background compensation;
- Visual and sound support of measurement procedure;
- Blocking of passage in case of personnel contamination;
- Automatic control of system configuration and detecting units performance;
- Possibility to control small objects;
- Accounting of personnel identification means during performance of measurement;
- External communications via RS485 or Ethernet;
- High mechanical strength of input/output blocking devices;
- External components made of stainless steel.
BASIC SPECIFICATIONS
Range of measured beta radiation energies, MeV |
from 0.1 to 2.5 |
Range of measured gamma radiation energies, MeV |
from 0.05 to 3 |
Beta flux density measurement range, particles/min*cm² |
from 1 to 1.5*104 |
Sensitivity of detecting unit to beta radiation of radionuclides 90Sr+90Y, cps/(particles/min*cm2), not less than |
2,2 |
Sensitivity of detecting unit to radiation of 137Cs, cps/kBq, not less than |
7 |
Limits for basic relative error of beta density flux measurement (P=0.95), %, not more than |
30 |
Detection time at beta contamination levels of 20 particles/min*cm², s, not more than |
5 |
Detection time of gamma radiation from 137Cs source with activity of 2 kBq, s, not more than |
5 |
Instability of sensitivity to beta radiation within 8 hours, %, not more than |
7 |
Power consumption, VA, not more than |
160 |
Power supply from single-phase AC line 220V 50Hz |
Overall dimensions, mm, not more than |
1000x1250x2500 |
Weight, kg, not more than |
500 |
|
| |
Print version
|
|