Aspect SPC
About the companyServicesContactsCertificates News     russian  
-Products-
Radiation Monitors and Systems
Dosimetry and radiometry
Nuclear radiation detectors
PC-based MCA
Modular nuclear electronics
Nuclear radiation spectrometers
Inspection systems
Shielding screens
Dedicated equipment
Software

Pedestrian and post-luggage
Vehicle
Mobile monitor YANTAR-MA-01
Integrated nuclear and radioactive materials monitoring system
RM-1SM
Automated radiation monitoring system AKRK-01M
New

To main page / Radiation Monitors and Systems

MOBILE RADIATION MONITOR YANTAR-MA-01

APPLICATION
  • outfit of radiation reconnaissance vehicles (vehicle, helicopter, launch);
  • radiation control with installation on port cranes, structure elements of conveyors, etc.
BASIC SET
  • Combined detector module MDK-01
    • gamma detector (plastic scintillator)
    • neutron detector (nine He-3 counters / ZnS(Ag):6LiF;)
  • Charge and power supply module UPS
  • Power supply and processing unit BPO
  • Occupancy sensor module MDP
  • Alarm module BOP
  • Operator's workstation based on industrial tablet computer with power supply unit

The sensitivity of the system can be increased by adding more MDK modules. One module BPO can control eight modules without additional hardware and software.

The systems can be optionally supplied with a video recording system, device of data binding to territory geographical coordinates GPS.

Detection thresholds, no more than
Cs - 137
490 kBq
Со - 60
245 kBq
Ва - 133
390 kBq
Рu
5 g
U
312 g
Рu shielded
80 g

Note:
Pu - sample of highly-enriched Pu-239, U - sample of highly-enriched U-235

Detection channels
gamma, neutron
Gamma detector
1 plastic 20.4 Ll
Neutron detector
9 counters 0.6 L each
Parameters of the search area
Width
3 m
Height
3 m
Speed of the target object
15 km/h
Power consumption
80 W
Operating temperature
From +5°С to +50°С
Overall dimensions of a pillar
450x1260x240 mm
MDK-01 weight
135 kg


Detection probability of the given masses of nuclear materials is 0.5 at level of confidence 95%, maximum background intensity 20 μR/h and maximum false alarm rate 1/1000

Note:
  • Can be supplied without neutron channel
  • Print version

    site map e-mail developed by cre8 bureau