RADIATION MONITOR RM-1SM

Used at entry control points in OFFICES

Detection thresholds, no more than
Cs - 137 360 kBq
Со - 60 180 kBq
Ва - 133 340 kBq
Рu 6 g
U 400 g

Pu - sample from Weapon Plutonium, U - sample from Weapon Uranium U-235

Detection channels
gamma
Gamma detector
1 plastic 0.8 l
Parameters of the search area1
Width
0.7 m
Height
2 m
Speed of the controlled object
5 km/h
Power consumption
20 W
Number of pillars with detectors
1
Overall dimensions of a pillar
125x750x70 mm
Weight
9.5 kg

1The claimed detection thresholds are duaranteed within the given parameters of the searsh area

Thresholds of radioactive and nuclear materials detection are given at detection probability of 0.5 at level of confidence 95%, maximum background intensity 20 μR/h, maximum false alarm rate 1/1000, parameters of the search area and speed of the object shown in the table.

The sensitivity of the system can be increased by adding more MDK modules. One module BPO can control eight modules without additional hardware and software.

The systems can be optionally supplied with a video recording system, device of data binding to territory geographical coordinates GPS.

Detection thresholds, no more than
Cs - 137
490 kBq
Со - 60
245 kBq
Ва - 133
390 kBq
Рu
5 g
U
312 g
Рu shielded
80 g

Note:
Pu - sample of highly-enriched Pu-239, U - sample of highly-enriched U-235

Detection channels
gamma, neutron
Gamma detector
1 plastic 20.4 Ll
Neutron detector
9 counters 0.6 L each
Parameters of the search area
Width
3 m
Height
3 m
Speed of the target object
15 km/h
Power consumption
80 W
Operating temperature
From +5°С to +50°С
Overall dimensions of a pillar
450x1260x240 mm
MDK-01 weight
135 kg


Detection probability of the given masses of nuclear materials is 0.5 at level of confidence 95%, maximum background intensity 20 μR/h and maximum false alarm rate 1/1000

Note:
  • Can be supplied without neutron channel
  • Print version